docs/high_resolution/high_resolution.rst

Fri, 19 Mar 2021 13:43:18 +0100

author
Giuseppe D'Amico <giuseppe.damico@imaa.cnr.it>
date
Fri, 19 Mar 2021 13:43:18 +0100
changeset 125
003aa42747f5
parent 116
5f36c691670e
permissions
-rw-r--r--

Update part concerning SCC data product file format description. Added also general section on basic lidar equations.

giuseppe@116 1 1. High Resolution products
ioannis@115 2 ======================================================
ioannis@115 3
giuseppe@116 4 #. Connect to https://scc.imaa.cnr.it
ioannis@115 5
giuseppe@116 6 #. Log-in with your username and password
ioannis@115 7
giuseppe@116 8 #. Click on "Station "Admin"
ioannis@115 9
giuseppe@116 10 .. figure:: media/add_hirelpp1.jpg
giuseppe@116 11 :height: 369
giuseppe@116 12 :width: 1037
giuseppe@116 13 :scale: 100 %
giuseppe@116 14 :align: center
ioannis@115 15
ioannis@115 16
giuseppe@116 17 #. In "Product settings" tab click on the "+" at the right of "HiRELPP Products"
ioannis@115 18
giuseppe@116 19 .. figure:: media/add_hirelpp2.jpg
ioannis@115 20 :height: 369
ioannis@115 21 :width: 1037
ioannis@115 22 :scale: 100 %
ioannis@115 23 :align: center
ioannis@115 24
giuseppe@116 25 #. Select "Min height" and "Max height"
ioannis@115 26
giuseppe@116 27 #. Select "Product types" and "Station"
ioannis@115 28
giuseppe@116 29 #. Select all the channels involved in the product calculation in the "Product/channel Connection"
ioannis@115 30
giuseppe@116 31 .. IMPORTANT::
giuseppe@116 32 HiRELPP products are designed to be multi-wavelength products. So do not define different HiRELPP products for different wavelengths but put all the wavelengths (channels) in the same HiRELPP product
ioannis@115 33
ioannis@115 34
giuseppe@116 35 #. Select the configuration at which the product should be connected in "System/Product Connection"
ioannis@115 36
giuseppe@116 37 #. On the base of the emission wavelengths of the channels included in the products, specify the emission wavelengths of the channels that have to be glued (separated by comma). If you leave this field empty the glueing will be NOT performed on any channel.
ioannis@115 38
giuseppe@116 39 #. (Optional) If among the channels included in the product, there are cross and parallel channels, select the depolarization calibration product(s) to use for their calibration under "polarization calibration product" and the "polarization option"
ioannis@115 40
giuseppe@116 41 #. Finally press "Save"
ioannis@115 42
giuseppe@116 43 .. figure:: media/add_hirelpp3.jpg
giuseppe@116 44 :height: 369
giuseppe@116 45 :width: 1037
ioannis@115 46 :scale: 100 %
ioannis@115 47 :align: center
ioannis@115 48
giuseppe@116 49 This is how the HiRELPP product should look like:
ioannis@115 50
giuseppe@116 51 .. figure:: media/add_hirelpp4.jpg
giuseppe@116 52 :height: 369
giuseppe@116 53 :width: 1037
ioannis@115 54 :scale: 100 %
ioannis@115 55 :align: center
ioannis@115 56
ioannis@115 57

mercurial