Wed, 14 Nov 2018 16:39:03 +0100
Added high resolution product documentation
ioannis@37 | 1 | .. _uploading_measurements: |
ioannis@37 | 2 | |
ioannis@37 | 3 | Uploading measurements |
ioannis@37 | 4 | ====================== |
ioannis@42 | 5 | |
ioannis@42 | 6 | New measurements can be uploaded using the "Quick Upload" link in the data |
ioannis@42 | 7 | processing submenu. There, you will need to fill and submit the provided form. |
ioannis@42 | 8 | |
ioannis@42 | 9 | |
ioannis@42 | 10 | Form fields |
ioannis@42 | 11 | ----------- |
ioannis@42 | 12 | |
ioannis@42 | 13 | System (Required) |
ioannis@42 | 14 | This field specifies the system configuration that was used to perform the |
ioannis@42 | 15 | measurement. The available systems can be managed in the "Station Admin" |
ioannis@42 | 16 | section of the site. You can later change the system used in the processing |
ioannis@42 | 17 | of the measurement again in the "Station Admin" section. |
ioannis@42 | 18 | |
ioannis@42 | 19 | Data file (Required) |
ioannis@42 | 20 | In this field you have to select the measurement file that will be processed. |
ioannis@42 | 21 | The file has to be in the specific format described in :ref:`netcdf_file`. |
ioannis@42 | 22 | |
ioannis@42 | 23 | Sounding file (Optional) |
ioannis@42 | 24 | In this optional field you can submit a sounding file that will be used |
ioannis@44 | 25 | by your measurements in the processing. The file needs to follow the netCDF |
ioannis@42 | 26 | file format specified in the pdf file found in the :ref:`netcdf_file` section. |
ioannis@42 | 27 | The file you submit will not be necessarily connected with the |
ioannis@42 | 28 | submitted measurement; which sounding file will be used in the processing of |
ioannis@42 | 29 | each measurement is specified in the measurement's file. The file you upload |
ioannis@42 | 30 | will, nevertheless, remain on the SCC and will be used whenever needed. |
ioannis@42 | 31 | |
ioannis@42 | 32 | Overlap file (Optional) |
ioannis@42 | 33 | In this optional field you can submit a overlap file that will be used |
ioannis@44 | 34 | by your measurements in the processing. The file needs to follow the netCDF |
ioannis@42 | 35 | file format specified in the pdf file found in the :ref:`netcdf_file` section. |
ioannis@42 | 36 | The file you submit will not be necessarily connected with the |
ioannis@42 | 37 | submitted measurement; which overlap file will be used in the processing of |
ioannis@42 | 38 | each measurement is specified in the measurement's file. The file you upload |
ioannis@42 | 39 | will, nevertheless, remain on the SCC and will be used whenever needed. |
ioannis@42 | 40 | |
ioannis@42 | 41 | Lidar ratio file (Optional) |
ioannis@42 | 42 | In this optional field you can submit a lidar ratio file that will be used |
ioannis@44 | 43 | by your measurements in the processing. The file needs to follow the netCDF |
ioannis@42 | 44 | file format specified in the pdf file found in the :ref:`netcdf_file` section. |
ioannis@42 | 45 | The file you submit will not be necessarily connected with the |
ioannis@42 | 46 | submitted measurement; which lidar ratio file will be used in the processing |
ioannis@42 | 47 | of each measurement is specified in the measurement's file. The file you |
ioannis@42 | 48 | upload will, nevertheless, remain on the SCC and will be used whenever needed. |
ioannis@42 | 49 | |
ioannis@50 | 50 | Comments (Optional) |
ioannis@50 | 51 | In this field you can add a small comment (up to 100 characters) to the |
ioannis@50 | 52 | measurement. |
ioannis@50 | 53 | |
ioannis@42 | 54 | Categories (Optional) |
ioannis@42 | 55 | You can assign a number of categories to the uploaded measurement. The |
ioannis@42 | 56 | categories you assign can be lated changed in the in the "Station Admin" |
ioannis@42 | 57 | section of the site. You can select multiple categories by holding down the |
ioannis@42 | 58 | "Control" key (PC) or "Command" key (MAC) while selecting. |
ioannis@42 | 59 | |
ioannis@42 | 60 | .. note:: |
ioannis@42 | 61 | |
ioannis@42 | 62 | Uploading the measurement file can take considerable time, depending on |
ioannis@42 | 63 | the size of the file and the speed of your Internet connection. In the |
ioannis@42 | 64 | current version of the site, no feedback is provided during the upload. |
ioannis@43 | 65 | You can get information on your upload progress depending on your browser. |
ioannis@42 | 66 | |
ioannis@42 | 67 | Firefox |
ioannis@43 | 68 | You can install this `add-on <https://addons.mozilla.org/en-US/firefox/addon/uploadprogress/>`_. |
ioannis@43 | 69 | |
ioannis@42 | 70 | Chrome |
ioannis@45 | 71 | A progress indicator is built-in. |
ioannis@42 | 72 | |
ioannis@42 | 73 | IE 9- |
ioannis@42 | 74 | No progress bar is available (as far as we know). |
ioannis@42 | 75 | |
ioannis@44 | 76 | |
ioannis@44 | 77 | Form Validation |
ioannis@44 | 78 | --------------- |
ioannis@44 | 79 | |
ioannis@46 | 80 | The aim of form validation is to detect errors in your submitted data as early |
ioannis@46 | 81 | as possible. In this way you can save time by correcting errors before the |
ioannis@46 | 82 | processing of your data fails. |
ioannis@46 | 83 | |
ioannis@46 | 84 | The data you provide in the form are check in two stages, before you submit |
ioannis@46 | 85 | and after you submit the form. |
ioannis@44 | 86 | |
ioannis@44 | 87 | Before you submit the form |
ioannis@44 | 88 | ~~~~~~~~~~~~~~~~~~~~~~~~~~ |
ioannis@44 | 89 | |
ioannis@44 | 90 | Before you submit the form the following checks are performed: |
ioannis@44 | 91 | |
ioannis@44 | 92 | * All the necessary fields (i.e. "system" and "data file") need to be submitted. |
ioannis@44 | 93 | |
ioannis@44 | 94 | * The ancillary file names have to be in the appropriate format described |
ioannis@44 | 95 | in :ref:`netcdf_file`. In brief, a sounding file should have a name |
ioannis@44 | 96 | rs_YYYYMMDDccNN.nc, a overlap file a name ov_YYYYMMDDccNN.nc, and a lidar ratio |
ioannis@44 | 97 | file a name lr_YYYYMMDDccNN.nc, where YYYY is a year, MM is the month, DD is |
ioannis@44 | 98 | the day, cc is the EARLINET station call sign and NN is a number. |
ioannis@44 | 99 | |
ioannis@44 | 100 | |
ioannis@44 | 101 | After you submit the form |
ioannis@44 | 102 | ~~~~~~~~~~~~~~~~~~~~~~~~~~ |
ioannis@44 | 103 | |
ioannis@44 | 104 | After you submit the form: |
ioannis@44 | 105 | |
ioannis@44 | 106 | * The uploaded **data file** needs to have a unique name. |
ioannis@44 | 107 | |
ioannis@44 | 108 | * The **measurement id** defined in the file should *not* exist in the SCC. |
ioannis@44 | 109 | |
ioannis@44 | 110 | * All channels declared in the measurement file should correspond to declared |
ioannis@44 | 111 | channels in the SCC. |
ioannis@44 | 112 | |
ioannis@44 | 113 | * The submitted measurement file should have the correct netCDF format. All |
ioannis@44 | 114 | mandatory variables and attributes should be present in the file. All |
ioannis@44 | 115 | variables and attributes should have the correct type (float, integer, etc). |
ioannis@44 | 116 | This check is not exhaustive, and it is possible that some errors are **not** |
ioannis@44 | 117 | detected. For example "conditionally" mandatory variables are not checked |
ioannis@44 | 118 | (as, for example "LR_Input", that is mandatory if elastic backscatter retrievals |
ioannis@44 | 119 | have to be done). |
ioannis@44 | 120 | |
ioannis@44 | 121 | If ancillary files are submitted |
ioannis@44 | 122 | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
ioannis@44 | 123 | |
ioannis@44 | 124 | Additionally, if ancillary files are also uploaded, the following checks are |
ioannis@44 | 125 | performed: |
ioannis@44 | 126 | |
ioannis@44 | 127 | * The submitted measurement file should have the correct netCDF format. All |
ioannis@44 | 128 | mandatory variables and attributes should be present in the file. All |
ioannis@44 | 129 | variables and attributes should have the correct type (float, integer, etc). |
ioannis@44 | 130 | |
ioannis@44 | 131 | * A file with the same filename should not exist in the SCC or, if it exists, |
ioannis@44 | 132 | it should have status "Missing" or "Error". If a file with the same filename |
ioannis@47 | 133 | exists, and its status is "OK" the submitted file is rejected. |