Thu, 17 Jun 2021 14:09:17 +0200
Updated documetation: new options for Molecular_Calc have been described
giuseppe@125 | 1 | SCC products filename |
giuseppe@125 | 2 | ============================== |
giuseppe@125 | 3 | |
giuseppe@125 | 4 | |
giuseppe@125 | 5 | The filename of all SCC products has the following structure:: |
giuseppe@125 | 6 | |
giuseppe@125 | 7 | |
giuseppe@125 | 8 | <station_code>_<product_type_ID>_<wavelength>_<productID>_<starttime>_<stoptime>_<measurementID>_<SCC_module>_<SCC\_version>.nc |
giuseppe@125 | 9 | |
giuseppe@125 | 10 | where: |
giuseppe@125 | 11 | |
giuseppe@125 | 12 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 13 | | *<station\_code>* | 3 digits code (for example pot) | |
giuseppe@125 | 14 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 15 | | *<product\_type\_ID>* | numeric 3 digits (for example 002) | |
giuseppe@125 | 16 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 17 | | *<wavelength>* | 4 digits reporting the wavelength in nm (for example 0532) | |
giuseppe@125 | 18 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 19 | | *<productID>* | numeric 7 digits (for example 0000213) | |
giuseppe@125 | 20 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 21 | | *<starttime>* | YYYYMMDDHHMM (for example 202102031832) | |
giuseppe@125 | 22 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 23 | | *<stoptime>* | YYYYMMDDHHMM (for example 202102031944) | |
giuseppe@125 | 24 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 25 | | *<measurementID>* | measurementID string (15 characters) | |
giuseppe@125 | 26 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 27 | | *<SCC\_module>* | SCC module (hirelpp,cloudscreen,elpp,eldec,elda,elic) | |
giuseppe@125 | 28 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 29 | | *<SCC\_version>* | SCC version (for example v5.2.0) | |
giuseppe@125 | 30 | +-----------------------+------------------------------------------------------------+ |
giuseppe@125 | 31 | |
giuseppe@125 | 32 | The field *<product\_type\_ID>* is codified as it follows: |
giuseppe@125 | 33 | |
giuseppe@125 | 34 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 35 | |Product\_type\_ID | Description | |
giuseppe@125 | 36 | +==================+======================================================+ |
giuseppe@125 | 37 | | *0* | Raman Bacskcatter | |
giuseppe@125 | 38 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 39 | | *1* | Extinction only | |
giuseppe@125 | 40 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 41 | | *2* | Lidar Ration and Extinction | |
giuseppe@125 | 42 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 43 | | *3* | Elastic Backscatter | |
giuseppe@125 | 44 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 45 | | *6* | Linear Polarization Calibration | |
giuseppe@125 | 46 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 47 | | *7* | Raman Backscatter and Linear Depolarization Ratio | |
giuseppe@125 | 48 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 49 | | *8* | Elastic Backscatter and Linear Depolarization Ratio | |
giuseppe@125 | 50 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 51 | | *9* | High Resolution Pre-Processed data | |
giuseppe@125 | 52 | +------------------+------------------------------------------------------+ |
giuseppe@125 | 53 | |
giuseppe@125 | 54 | |
giuseppe@125 | 55 | The field *<wavelength>* is available only for ELEC and ELDA data products (for all the other SCC data products is missing). |
giuseppe@125 | 56 | For CloudScreen products the fields *<product\_type\_ID>*, *<wavelength>*, *<productID>* are missing. |
giuseppe@125 | 57 |