docs/faq/faq.rst

Mon, 06 Feb 2017 14:02:43 +0200

author
Iannis <ulalume3@yahoo.com>
date
Mon, 06 Feb 2017 14:02:43 +0200
changeset 100
7a2166a28044
parent 83
44e5ebae6813
child 127
88d912df1073
permissions
-rw-r--r--

Removed old format-related files from VC.

binietoglou@23 1 Frequently asked questions
binietoglou@23 2 ==========================
binietoglou@23 3
ioannis@39 4
ioannis@39 5 Using an ancillary file
ioannis@39 6 ~~~~~~~~~~~~~~~~~~~~~~~
ioannis@39 7
binietoglou@83 8 Q: I use the "Quick upload" to submit a measurement file together with an ancillary
ioannis@40 9 file. Will this ancillary file be used in the processing of my measurement.
ioannis@39 10
ioannis@39 11 A: No. Which ancillary file is used when processing a measurement is defined in the
ioannis@39 12 measurement netcdf file. If your new ancillary file is not mentioned in the measurement
ioannis@39 13 file, it will not be used.
ioannis@39 14
ioannis@39 15
ioannis@39 16 Reusing an ancillary file
ioannis@39 17 ~~~~~~~~~~~~~~~~~~~~~~~~~
ioannis@39 18
ioannis@39 19 Q: I want to use one ancillary file (ex. an overlap file) in the processing of multiple
ioannis@39 20 measurements. Do I need to submit it multiple times?
ioannis@39 21
ioannis@39 22 A: No. You just need to define the file name of the file to use in the measurements
ioannis@39 23 netcdf file.
ioannis@39 24
ioannis@39 25
ioannis@39 26 Deleting an ancillary file
ioannis@39 27 ~~~~~~~~~~~~~~~~~~~~~~~~~~
ioannis@39 28
ioannis@39 29 Q: I want to delete an uploaded ancillary file but in the "Admin" interface I can't
ioannis@39 30 find a "Delete" button.
ioannis@39 31
ioannis@39 32 A: Probably the ancillary file you are trying to delete is needed by some uploaded
ioannis@39 33 measurement, and for this reason you are not allowed to delete it. You will need
ioannis@39 34 to delete the corresponding measurements first, before deleting the ancillary file.
ioannis@39 35
ioannis@39 36
ioannis@39 37
binietoglou@24 38 Clouds in the data
binietoglou@24 39 ~~~~~~~~~~~~~~~~~~
binietoglou@23 40
binietoglou@29 41 Q: Is it necessary to provide only measurement periods with cloud free conditions and
binietoglou@29 42 homogeneous atmosphere or is this part of ELDA or the pre-processing of the data?
binietoglou@24 43 For example in cases with scattered low cumulus clouds.
binietoglou@24 44
binietoglou@24 45 A: At moment you should provide cloud free data because the automatic cloud screening
binietoglou@23 46 is not yet implemented in the SCC. We are working on this issue and hopefully the new
ioannis@39 47 module will be implemented at the end of ACTRIS project.
binietoglou@23 48
binietoglou@23 49
ulalume3@79 50 Minimum number of analog files to submit
ulalume3@79 51 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
ulalume3@79 52
ulalume3@79 53 Q: Is it possible to submit a single analog profile for processing?
ulalume3@79 54
ulalume3@79 55
ulalume3@79 56 A: It depepends on the type of product you ar trying to calculate.
ulalume3@79 57
ulalume3@79 58 * If the product is a linear polarization calibration, it is possible to submit a timeseries containing
ulalume3@80 59 one single analog profile. This is allowed because some stations are performing depolarization calibration measurements using
ulalume3@80 60 single profiles. If the errors are present they will be taken into account for the calculation of the error on calibration constant.
ulalume3@80 61 If they are not the error on calibration constant is calculate as the standard deviation withing the calibration range.
ulalume3@79 62
ulalume3@79 63 * If the product to calculate is NOT a linear polarization calibration, if the raw analog error have not been provided we need at
ulalume3@80 64 least 3 raw profile in order to compute the statistical error
ulalume3@79 65
ulalume3@79 66
binietoglou@24 67 High/low range channels
binietoglou@24 68 ~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@24 69 Q: What is the definition of low range, ultra near range and high range channels?
binietoglou@24 70 Are there any threshold values?
binietoglou@24 71
binietoglou@24 72 A: There are no threshold values defined for the different range types. This information
binietoglou@23 73 is used only in the gluing procedures just to identify which channel should be taken
binietoglou@23 74 as low range and which one as far range. If no gluing is applied by the SCC the range
binietoglou@23 75 id flags are not taken into account.
binietoglou@23 76
binietoglou@23 77
binietoglou@24 78 Extra netcdf parameters
binietoglou@24 79 ~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@24 80 Q: Is it possible for documentation purposes to put own parameters in the SCC-NetCDF file?
binietoglou@24 81 For example who created the file.... Are there any reasons against this?
binietoglou@23 82
binietoglou@24 83 A: Technically as long as you use not standard SCC variables for your own parameters there are
binietoglou@23 84 no problems for the SCC. It will just ignore these not standard variables.
binietoglou@23 85
binietoglou@23 86
binietoglou@24 87 Netcdf version
binietoglou@24 88 ~~~~~~~~~~~~~~
binietoglou@24 89 Q: Which NetCDF version is to use? NetCDF3, NetCDF3 Classic, NetCDF4, NetCDF4 Classic?
binietoglou@24 90
binietoglou@24 91 A: The NetCDF libraries 4.1.3 are used in all the SCC modules. So all the NetCDF formats you
binietoglou@23 92 have indicated should be compatible with the SCC (we have tested NetCDF3 and NetCDF4).
binietoglou@23 93
binietoglou@81 94
binietoglou@24 95 Lidar ratio
binietoglou@24 96 ~~~~~~~~~~~
binietoglou@24 97 Q: What are the values for the lidar ratio used in the SCC_DB?
binietoglou@23 98
binietoglou@24 99 A: The values of (fixed) lidar ratio used by the SCC in the elastic retrieval can be set by
binietoglou@23 100 the user using the SCC web interface. In particular you can define a lidar ratio value for
binietoglou@24 101 each elastic backscatter product: in the product page there is the section "Elastic Backscatter
binietoglou@24 102 options" in which there is the field "Fixed lr". In case you want to use a lidar ratio profile
binietoglou@23 103 you should set LR_Input accordingly and provide an external LR profile NetCDF file
binietoglou@23 104 (see documentation on SCC file format).
binietoglou@23 105
binietoglou@29 106 Calculation of Raman and elastic backscatter
binietoglou@29 107 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@24 108 Q: In cases of measurements where Raman channels are available, the SCC will calculate the Raman
binietoglou@24 109 backscatter profile. If I want to retrieve Klett-retrievals for this channel, too (e.g 532nm)
binietoglou@24 110 is it sufficient to set the value in LR_input(channels) to 1 or 0 plus a LR-profile to get
binietoglou@24 111 both retrievals?
binietoglou@23 112
binietoglou@24 113 A: No. In general, for each lidar configuration you can define a set of optical products to be calculated
binietoglou@23 114 for that configuration using the SCC web interface. So suppose you have a system with 532nm and 607nm
binietoglou@23 115 channels. In this case you have 2 options:
binietoglou@24 116
binietoglou@24 117 1. Raman backscatter and extinction in the e532 file and Raman backscatter (full resolution) in the b532
binietoglou@24 118 file. In this case you should associate to the configuration a product of type "lidar ratio and will
binietoglou@24 119 produce the e532 file and a product of type "Raman backscatter" which will produce the b532 file
binietoglou@24 120 2. Raman backscatter and extinction in the e532 file and elastic backscatter in the b532 file.
binietoglou@24 121 In this case you should associate to the configuration a product of type "lidar ratio and extinction"
binietoglou@24 122 which will produce the e532 file and a product of type "elastic backscatter" which will produce the b532 file
binietoglou@23 123
binietoglou@23 124 Note: you cannot calculate a b532 file containing the Raman and elastic backscatters at the same time.
binietoglou@23 125 The reason is that the 2 products will produce an output file with the same name (according to the EARLINET rules).
binietoglou@23 126 Moreover in general, it makes no sense to calculate the elastic backscatter when you can calculate the Raman
binietoglou@23 127 one which usually is better.
binietoglou@23 128
binietoglou@81 129
binietoglou@24 130 Filename conventions
binietoglou@24 131 ~~~~~~~~~~~~~~~~~~~~
ioannis@54 132 Q: What are the conventions for the filenames for the various files that need to be uploaded?
binietoglou@23 133
ioannis@54 134 A: The following definitions apply:
binietoglou@23 135
binietoglou@29 136 SCC raw lidar data file
binietoglou@29 137 ^^^^^^^^^^^^^^^^^^^^^^^
binietoglou@29 138
ioannis@55 139 In the current version of the SCC there is not limit in the name of the raw
ioannis@55 140 data file. We suggest, however, that this file is named <measurement_id>.nc.
ioannis@55 141 For example, if your measurement had a measurement ID of 20130101cc00 the
ioannis@55 142 corresponding NetCDF file should be named 20130101cc00.nc
binietoglou@23 143
binietoglou@24 144 Sounding file
binietoglou@24 145 ^^^^^^^^^^^^^
binietoglou@23 146
binietoglou@23 147 The file should be named as rs_measID.nc. Considering the above example the sounding file should be named rs_20130101cc00.nc
binietoglou@23 148
binietoglou@29 149 In this case you should also set the global attribute Sounding_File_Name in the raw lidar data file as::
binietoglou@23 150
binietoglou@29 151 Sounding_File_Name=rs_20130101cc00.nc
binietoglou@23 152
binietoglou@24 153 Lidar ratio file
binietoglou@24 154 ^^^^^^^^^^^^^^^^
binietoglou@23 155 The file should be named as lr_measID.nc. Considering the above example the sounding file should be named lr_20130101cc00.nc
binietoglou@23 156
binietoglou@29 157 In this case you should also set the global attribute LR_File_Name in the raw lidar data file as::
binietoglou@23 158
binietoglou@29 159 LR_File_Name=lr_20130101cc00.nc
binietoglou@23 160
binietoglou@24 161 Overlap file
binietoglou@24 162 ^^^^^^^^^^^^
binietoglou@23 163 The file should be named as ov_measID.nc. Considering the above example the sounding file should be named ov_20130101cc00.nc
binietoglou@23 164
binietoglou@29 165 In this case you should also set the global attribute Overlap_File_Name in the raw lidar data file as::
binietoglou@29 166
binietoglou@29 167 Overlap_File_Name=ov_20130101cc00.nc
binietoglou@29 168
binietoglou@29 169
binietoglou@29 170 Photocounting values should be integers
binietoglou@29 171 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@29 172 Q: In one of my measurements I get an error concerning the photoncounting values::
binietoglou@29 173
binietoglou@29 174 Pre processing (177): Found no integer values in photoncounting signal
binietoglou@29 175
binietoglou@29 176 The Raw_Lidar_Data variable in the NetCDF-file is defined as double. So is it necessary for Photoncounting signals to only provide integer values?
binietoglou@29 177
binietoglou@29 178 A: Two important considerations:
binietoglou@23 179
binietoglou@29 180 1. The Raw_Lidar_Data array should contain your *real* raw data.
binietoglou@29 181 This means that *no corrections/operations* should be made on your signals
binietoglou@29 182 before filling the Raw_Lidar_Data array. This is particularly important because *all*
binietoglou@29 183 the operations and corrections should be applied by the SCC and not by the user before
binietoglou@29 184 the submission. In this way we can keep track of all the operations made on the signals
binietoglou@29 185 (for QA purposes) and moreover we are sure that all the corrections are applied in a
binietoglou@29 186 correct order (this is particularly important for non linear operations, think for example to the dead time correction).
binietoglou@29 187
binietoglou@29 188 2. The analog signals should be expressed in mV and the photoncounting signals in raw counts
binietoglou@29 189
binietoglou@29 190 So if your photoncounting values are not integers they are not expressed in raw counts (which of course should be integers).
binietoglou@29 191 So the point here is not how to convert them in integers but to submit the right quantity in the right units.
binietoglou@29 192
binietoglou@29 193 So please check carefully your converter and be sure to really submit raw counts for photoncounting channels and raw mV for the analog ones.
binietoglou@29 194
binietoglou@29 195
binietoglou@29 196 Preprocessing failed but no Exit code is provided
binietoglou@29 197 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@29 198 Q: The preprocessing of one of my measurements failed (I get a status -127). However, when I check the Exit codes
binietoglou@29 199 to see the description of the problem, I get an empty value (-). What does this mean?
binietoglou@29 200
binietoglou@29 201 A: This means that the preprocessor crushed unexpectedly! Sorry for that! Report the problem in the forum and it will be fixed
binietoglou@29 202 soon.

mercurial