docs/faq/faq.rst

Wed, 20 Feb 2013 15:23:54 +0100

author
ulalume3 <binietoglou@imaa.cnr.it>
date
Wed, 20 Feb 2013 15:23:54 +0100
changeset 27
e20498e04e1a
parent 24
8291320ffe74
child 29
44196e354b52
permissions
-rw-r--r--

Added usecase image files.

binietoglou@23 1 Frequently asked questions
binietoglou@23 2 ==========================
binietoglou@23 3
binietoglou@24 4 Clouds in the data
binietoglou@24 5 ~~~~~~~~~~~~~~~~~~
binietoglou@23 6
binietoglou@24 7 Q: Is it necessary to provide only measurment periods with cloud free conditions and
binietoglou@24 8 homogeneous atmosphere or is this part of ELDA or the pre processing of the data?
binietoglou@24 9 For example in cases with scattered low cumulus clouds.
binietoglou@24 10
binietoglou@24 11 A: At moment you should provide cloud free data because the automatic cloud screening
binietoglou@23 12 is not yet implemented in the SCC. We are working on this issue and hopefully the new
binietoglou@23 13 module will be implemented at the end of ACTRIS project .
binietoglou@23 14
binietoglou@23 15
binietoglou@24 16 High/low range channels
binietoglou@24 17 ~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@24 18 Q: What is the definition of low range, ultra near range and high range channels?
binietoglou@24 19 Are there any threshold values?
binietoglou@24 20
binietoglou@24 21 A: There are no threshold values defined for the different range types. This information
binietoglou@23 22 is used only in the gluing procedures just to identify which channel should be taken
binietoglou@23 23 as low range and which one as far range. If no gluing is applied by the SCC the range
binietoglou@23 24 id flags are not taken into account.
binietoglou@23 25
binietoglou@24 26 Variable depolarization factor
binietoglou@24 27 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@24 28
binietoglou@24 29 Q: Due to changes in the settings of our lidarsystem, the depolarization factor can
binietoglou@24 30 change during the measurement. Is it necessary to provide one SCC-file for each settings
binietoglou@24 31 or is it possible to set the Depolarization_Factor variable time dependent?
binietoglou@23 32
binietoglou@24 33 A: Unfortunately it is not possible to have time dependence on Depolarization_Factor variable.
binietoglou@23 34 So if this parameter changes you should provide different SCC files for each setting.
binietoglou@23 35
binietoglou@24 36 Extra netcdf parameters
binietoglou@24 37 ~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@24 38 Q: Is it possible for documentation purposes to put own parameters in the SCC-NetCDF file?
binietoglou@24 39 For example who created the file.... Are there any reasons against this?
binietoglou@23 40
binietoglou@24 41 A: Technically as long as you use not standard SCC variables for your own parameters there are
binietoglou@23 42 no problems for the SCC. It will just ignore these not standard variables.
binietoglou@23 43
binietoglou@23 44
binietoglou@24 45 Netcdf version
binietoglou@24 46 ~~~~~~~~~~~~~~
binietoglou@24 47 Q: Which NetCDF version is to use? NetCDF3, NetCDF3 Classic, NetCDF4, NetCDF4 Classic?
binietoglou@24 48
binietoglou@24 49 A: The NetCDF libraries 4.1.3 are used in all the SCC modules. So all the NetCDF formats you
binietoglou@23 50 have indicated should be compatible with the SCC (we have tested NetCDF3 and NetCDF4).
binietoglou@23 51
binietoglou@24 52 Lidar ratio
binietoglou@24 53 ~~~~~~~~~~~
binietoglou@24 54 Q: What are the values for the lidar ratio used in the SCC_DB?
binietoglou@23 55
binietoglou@24 56 A: The values of (fixed) lidar ratio used by the SCC in the elastic retrieval can be set by
binietoglou@23 57 the user using the SCC web interface. In particular you can define a lidar ratio value for
binietoglou@24 58 each elastic backscatter product: in the product page there is the section "Elastic Backscatter
binietoglou@24 59 options" in which there is the field "Fixed lr". In case you want to use a lidar ratio profile
binietoglou@23 60 you should set LR_Input accordingly and provide an external LR profile NetCDF file
binietoglou@23 61 (see documentation on SCC file format).
binietoglou@23 62
binietoglou@24 63 Calculation of raman and elastic backsatter
binietoglou@24 64 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
binietoglou@24 65 Q: In cases of measurements where Raman channels are available, the SCC will calculate the Raman
binietoglou@24 66 backscatter profile. If I want to retrieve Klett-retrievals for this channel, too (e.g 532nm)
binietoglou@24 67 is it sufficient to set the value in LR_input(channels) to 1 or 0 plus a LR-profile to get
binietoglou@24 68 both retrievals?
binietoglou@23 69
binietoglou@24 70 A: No. In general, for each lidar configuration you can define a set of optical products to be calculated
binietoglou@23 71 for that configuration using the SCC web interface. So suppose you have a system with 532nm and 607nm
binietoglou@23 72 channels. In this case you have 2 options:
binietoglou@24 73
binietoglou@24 74 1. Raman backscatter and extinction in the e532 file and Raman backscatter (full resolution) in the b532
binietoglou@24 75 file. In this case you should associate to the configuration a product of type "lidar ratio and will
binietoglou@24 76 produce the e532 file and a product of type "Raman backscatter" which will produce the b532 file
binietoglou@24 77 2. Raman backscatter and extinction in the e532 file and elastic backscatter in the b532 file.
binietoglou@24 78 In this case you should associate to the configuration a product of type "lidar ratio and extinction"
binietoglou@24 79 which will produce the e532 file and a product of type "elastic backscatter" which will produce the b532 file
binietoglou@23 80
binietoglou@23 81 Note: you cannot calculate a b532 file containing the Raman and elastic backscatters at the same time.
binietoglou@23 82 The reason is that the 2 products will produce an output file with the same name (according to the EARLINET rules).
binietoglou@23 83 Moreover in general, it makes no sense to calculate the elastic backscatter when you can calculate the Raman
binietoglou@23 84 one which usually is better.
binietoglou@23 85
binietoglou@24 86 Filename conventions
binietoglou@24 87 ~~~~~~~~~~~~~~~~~~~~
binietoglou@24 88 A: What are the conventions for the filnames for the various files that need to be uploaded?
binietoglou@23 89
binietoglou@24 90 Q: The following definitions apply:
binietoglou@23 91 - SCC raw lidar data file
binietoglou@23 92
binietoglou@23 93 This file should be named as measID.nc. For example if your measurement had a measurementID of 20130101cc00 the corresponding NetCDF file should be named 20130101cc00.nc
binietoglou@23 94
binietoglou@24 95 Sounding file
binietoglou@24 96 ^^^^^^^^^^^^^
binietoglou@23 97
binietoglou@23 98 The file should be named as rs_measID.nc. Considering the above example the sounding file should be named rs_20130101cc00.nc
binietoglou@23 99
binietoglou@23 100 In this case you should also set the global attribute Sounding_File_Name in the raw lidar data file as:
binietoglou@23 101
binietoglou@23 102 Sounding_File_Name=rs_20130101cc00.nc
binietoglou@23 103
binietoglou@24 104 Lidar ratio file
binietoglou@24 105 ^^^^^^^^^^^^^^^^
binietoglou@23 106 The file should be named as lr_measID.nc. Considering the above example the sounding file should be named lr_20130101cc00.nc
binietoglou@23 107
binietoglou@23 108 In this case you should also set the global attribute LR_File_Name in the raw lidar data file as:
binietoglou@23 109
binietoglou@23 110 LR_File_Name=lr_20130101cc00.nc
binietoglou@23 111
binietoglou@24 112 Overlap file
binietoglou@24 113 ^^^^^^^^^^^^
binietoglou@23 114 The file should be named as ov_measID.nc. Considering the above example the sounding file should be named ov_20130101cc00.nc
binietoglou@23 115
binietoglou@23 116 In this case you should also set the global attribute Overlap_File_Name in the raw lidar data file as:
binietoglou@23 117
binietoglou@23 118 Overalp_File_Name=ov_20130101cc00.nc

mercurial