361 | 1064 | 6 | elT | x | x | |
361 | 1064 | 6 | elT | x | x | |
362 +----------------+--------------+----------------+-------------+-----------+ |
362 +----------------+--------------+----------------+-------------+-----------+ |
363 |
363 |
364 The other change about the polarization channels required to run the SCC v4.0 is the definition of the polarization crosstalk parameters for all the polarization channels available. Such parameters can be defined for each polarization channel using the SCC web interface (see figure 3.2). In particular among the channel parameters there is a new tab called *Polarization crosstalk parameters* where it is possible to insert the values from for the parameters *G* and *H* and the corresponding statistical and systematic errors if available. In case you have measured *G* and *H* for your polarization channels please insert the corresponding values there. Otherwise you can insert the ideal values as reported in table 1.1. |
364 The other change about the polarization channels required to run the SCC v4.0 is the definition of the polarization crosstalk parameters for all the polarization channels available. Such parameters can be defined for each polarization channel using the SCC web interface (see figure 3.2). In particular among the channel parameters there is a new tab called *Polarization crosstalk parameters* where it is possible to insert the values from for the parameters *G* and *H* and the corresponding statistical and systematic errors if available. In case you have measured *G* and *H* for your polarization channels please insert the corresponding values there. Otherwise you can insert the ideal values as reported in table 1.1. |
365 |
365 |
366 .. figure:: ../media/figure3.2.png |
366 .. figure:: media/figure3.2.png |
367 :height: 479 |
367 :height: 479 |
368 :width: 1890 |
368 :width: 1890 |
369 :scale: 100 % |
369 :scale: 100 % |
370 :align: center |
370 :align: center |
371 |
371 |
396 |
396 |
397 Finally we should add to the configuration “depol_calibration” a product “*Linear polarization calibration”* to be used for the calibration. According to the example given above and to the usecase document attached we should use an usecase=4 for this example. |
397 Finally we should add to the configuration “depol_calibration” a product “*Linear polarization calibration”* to be used for the calibration. According to the example given above and to the usecase document attached we should use an usecase=4 for this example. |
398 |
398 |
399 Other “*Linear polarization calibration”* options to be specified are reported in figure 3.3. The most important factor you should insert here is the *Pol calibration correction factor* (K). The ideal value for this parameter is 1. Anyway if you have measured the parameter K please fill in the measured value and the corresponding measurement errors. |
399 Other “*Linear polarization calibration”* options to be specified are reported in figure 3.3. The most important factor you should insert here is the *Pol calibration correction factor* (K). The ideal value for this parameter is 1. Anyway if you have measured the parameter K please fill in the measured value and the corresponding measurement errors. |
400 |
400 |
401 .. figure:: ../media/figure3.3.png |
401 .. figure:: media/figure3.3.png |
402 :height: 495 |
402 :height: 495 |
403 :width: 1887 |
403 :width: 1887 |
404 :scale: 100 % |
404 :scale: 100 % |
405 :align: center |
405 :align: center |
406 |
406 |
681 |
681 |
682 As you can see in table 3.5, the old product IDs=3 and 6 (present in table 3.4) have been replaced with the new product ID=10 and 11 to guarantee the calculation of *PLDR*. |
682 As you can see in table 3.5, the old product IDs=3 and 6 (present in table 3.4) have been replaced with the new product ID=10 and 11 to guarantee the calculation of *PLDR*. |
683 |
683 |
684 It is important to set among the product options of the product ID=10 and 11 which calibration product we want to use for calibration (see section 3.2). This can be done using the SCC web interface setting the appropriate setting in the tab *Polarization calibration products* (see figure 3.4). According to the current example you should set here the calibration product defined in section 3.2. |
684 It is important to set among the product options of the product ID=10 and 11 which calibration product we want to use for calibration (see section 3.2). This can be done using the SCC web interface setting the appropriate setting in the tab *Polarization calibration products* (see figure 3.4). According to the current example you should set here the calibration product defined in section 3.2. |
685 |
685 |
686 .. figure:: ../media/figure3.4.png |
686 .. figure:: media/figure3.4.png |
687 :height: 102 |
687 :height: 102 |
688 :width: 1895 |
688 :width: 1895 |
689 :scale: 100 % |
689 :scale: 100 % |
690 :align: center |
690 :align: center |
691 |
691 |