docs/administration/adding_products.rst

Wed, 09 Jul 2014 17:47:38 +0300

author
Iannis <ioannis@inoe.ro>
date
Wed, 09 Jul 2014 17:47:38 +0300
changeset 57
2c95a0843b64
parent 56
42ab98661928
child 58
a11cb3748526
permissions
-rw-r--r--

Corrected title length

Products
========

Depending on the product you need to produce, some of the following tables need to be filled. 


.. note::

   This section is not up-to-date to the latest interface version.

.. note::

   Each product should be connected to a system before being saved.
   

Backscatter products
--------------------
The following tables need to be filed for the various backscatter products.

Backscatter calibrations 
------------------------
For backscatter (product types: Raman backscatter, Combined Raman backscatter and extinction, Elastic backscatter retrieval

LowestHeight   
   in meters, lowest height for reference height search

TopHeight
   in meters, maximum height for reference height search

WindowWidth
   in meters, width of the reference height interval

calValue
   backscatter ratio, e.g. 1 or 1.01
   
calRangeSearchMethod ID: 
   always 0
   
   
If done, you have to remember the ID for your backscatter calibration options an go the the specific tables below,

for product type 0 and 2: Raman_backscatter_options
---------------------------------------------------

Raman calculation method
   at the moment, only 1
   
bsc cal options
   insert ID from previous step
   
error method ID: 
   at the moment, only 1
   
for product type 3: elast_backscatter_options
-----------------------------------------------

 elast bsc method ID
   at the moment, only 1 (iterative approach)
   
bsc cal options
   insert ID from previous step
   
error method ID: 
   at the moment, only 1
      
lr input id:
   at the moment, only 1 (fixed LR)
   
fixed_lr
   ... in sr, value of the used lidar ratio
   
iter_bsc_options
   if, iterative approach is used, go to table iter_bsc_options and remember ID and insert here

iter_bsc_options
----------------

iter conv crit
   ...e.g. 0.1 (=10%) The iteration is stopped when the RELATIVE difference between the actual and the previous column integrated backscatter coefficients is below this value

ram bsc method id
   at the moment, only 1
   
max iteration count: 
   maximum number of iteration steps   

for product type 1: Extinction options
--------------------------------------

Extinction method:
   Standard: 1, (0 weighted linear fit, 1 non-weighted linear fit, 2 difference quotient, 3 polynomial sec order fit, 4 quadratic function, 5 Savitzky-Golay filter, 6 Russo)

error method ID: 
   at the moment, only 1
   
overlap file ID:
   if overlap file is available, enter ID here
   
angstroem: 
   used angström value for the extinction calculation, e.g. 0,1, or 1.5
   
for product type 2: Ext bsc options
-----------------------------------

product ID
   ID of product type 2
   
extinction option product ID
   ID of the extinction product (see table products)
   
raman backscatter options product ID
    ID of the Raman backscatter product (see table products)
    
error method ID: 
   at the moment, only 1
   

mercurial