output_files/example lidar-optic_input_example_lidar-GHK.dat

changeset 28
79fa4a41420f
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/output_files/example lidar-optic_input_example_lidar-GHK.dat	Thu Jan 24 21:24:25 2019 +0100
@@ -0,0 +1,48 @@
+From folder C:\Users\volker\Documents\atmospheric_lidar_ghk
+Running prog lidar_correction_ghk_0.9.8d_Py3.7.py
+Version 0.9.8d
+Reading input file  optic_input_example_lidar.py
+for Lidar system:  xx ,  example lidar
+ --- Input parameters: value ±error / ±steps  ----------------------
+Laser: DOLP = 0.9950± 0.0050/ 1;  Rotation alpha =     0.0000± 2.0000/ 1
+              Diatt.,             Tunpol,   Retard.,   Rotation (deg)
+Emitter       0.0000± 0.1000/ 0,  1.0000,   0±180/ 0,  0.0000± 1.0000/ 0
+Receiver      0.0000± 0.2000/ 1,  1.0000,   0±180/ 0,  0.0000± 0.1000/ 0
+Calibrator    0.9998± 0.0002/ 1,  0.4000,   0±180/ 3,  0.0000± 0.1000/ 0
+ --- Pol.-filter ---
+ERT, RotT       : 0.0010± 0.0010/ 0,  0.0000± 1.0000/ 0
+ERR, RotR       : 0.0010± 0.0010/ 1, 90.0000± 1.0000/ 1
+ --- PBS ---
+TP,TS           : 0.9500± 0.0100/ 1,  0.0050± 0.0010/ 1
+RP,RS           : 0.0500± 0.0000/ 0,  0.9950± 0.0000/ 0
+DT,TT,DR,TR,Y   : 0.9895, 0.4775, -0.9043, 0.5225, 1
+ --- Combined PBS + Pol.-filter ---
+DT,TT,DR,TR     : 1.0000, 0.4750, -0.9999, 0.4975
+LDRCal during calibration in calibration range:  0.200± 0.150/ 1
+ --- Additional ND filter attenuation (transmission) during the calibration ---
+TCalT,TCalR      : 1.0000± 0.0100/ 0,  0.1000± 0.0010/ 1
+
+Rotation Error Epsilon For Normal Measurements =  False
+linear polarizer before receiver
+Parallel signal detected in transmitted channel
+RS_RP_depend_on_TS_TP =  True
+
+IoutTp, IoutTm, IoutRp, IoutRm, It    , Ir    , dIoutTp, dIoutTm, dIoutRp, dIoutRm, dIt, dIr
+===========================================================================================================
+ GR     , GT     , HR     , HT     ,  K(0.004), K(0.02),  K(0.1) ,  K(0.2) ,  K(0.3) ,  K(0.45)
+ 1.00000, 1.00000,-0.99490, 0.99499,  0.96129,  0.96248,  0.96796,  0.97382,  0.97880,  0.98502
+===========================================================================================================
+
+Errors from neglecting GHK corrections and/or calibration:
+   LDRtrue, LDRunCorr,1/LDRunCorr,   LDRsimx, 1/LDRsimx,   LDRCorr
+   0.00400,   0.00673, 148.53471,   0.00687, 145.62357,   0.00400
+   0.02000,   0.02316,  43.17641,   0.02362,  42.33019,   0.02000
+   0.10000,   0.10528,   9.49823,   0.10739,   9.31207,   0.10000
+   0.30000,   0.31044,   3.22120,   0.31665,   3.15806,   0.30000
+   0.45000,   0.46418,   2.15434,   0.47346,   2.11212,   0.45000
+LDRsimx = LDR of the nominal system directly from measured signals without  calibration and GHK-corrections
+LDRunCorr = LDR of the nominal system directly from measured signals with calibration but without  GHK-corrections; electronic amplifications = 1 assumed
+LDRCorr = LDR calibrated and GHK-corrected
+
+Errors from signal noise:
+Signal counts: NCalT, NCalR, NILfac, nNCal, nNI =      50000,     50000,  2, 0, 0

mercurial